Line |
Item Number |
Description |
Units |
Quantity |
1 |
2021.501 |
MOBILIZATION |
LUMP SUM |
1 |
2 |
2031.502 |
FIELD OFFICE |
EACH |
1 |
3 |
2101.502 |
CLEARING |
EACH |
17 |
4 |
2101.502 |
GRUBBING |
EACH |
17 |
5 |
2102.503 |
PAVEMENT MARKING REMOVAL |
LIN FT |
12,789 |
6 |
2102.518 |
PAVEMENT MARKING REMOVAL |
SQ FT |
368 |
7 |
2103.501 |
BUILDING REMOVAL A |
LUMP SUM |
1 |
8 |
2103.501 |
BUILDING REMOVAL B |
LUMP SUM |
1 |
9 |
2103.501 |
BUILDING REMOVAL C |
LUMP SUM |
1 |
10 |
2103.501 |
BUILDING REMOVAL D |
LUMP SUM |
1 |
11 |
2103.501 |
BUILDING REMOVAL E |
LUMP SUM |
1 |
12 |
2104.502 |
ABANDON CATCH BASIN OR MANHOLE |
EACH |
1 |
13 |
2104.502 |
REMOVE CASTING |
EACH |
26 |
14 |
2104.502 |
REMOVE CONCRETE STEPS |
EACH |
1 |
15 |
2104.502 |
REMOVE DELINEATOR / MARKER |
EACH |
1 |
16 |
2104.502 |
REMOVE MAIL BOX SUPPORT |
EACH |
8 |
17 |
2104.502 |
REMOVE MANHOLE OR CATCH BASIN |
EACH |
22 |
18 |
2104.502 |
REMOVE SIGN |
EACH |
29 |
19 |
2104.502 |
REMOVE SIGNAL SYSTEM A |
EACH |
1 |
20 |
2104.502 |
REMOVE SIGNAL SYSTEM B |
EACH |
1 |
21 |
2104.502 |
SALVAGE SIGN |
EACH |
3 |
22 |
2104.502 |
SALVAGE TREE GRATE |
EACH |
6 |
23 |
2104.503 |
REMOVE CURB AND GUTTER |
LIN FT |
4,240 |
24 |
2104.503 |
REMOVE SEWER PIPE (STORM) |
LIN FT |
1,141 |
25 |
2104.503 |
SALVAGE RETAINING WALL |
LIN FT |
25 |
26 |
2104.503 |
SAWING BITUMINOUS PAVEMENT (FULL DEPTH) |
LIN FT |
538 |
27 |
2104.503 |
SAWING CONCRETE PAVEMENT (FULL DEPTH) |
LIN FT |
544 |
28 |
2104.504 |
REMOVE BITUMINOUS DRIVEWAY PAVEMENT |
SQ YD |
115 |
29 |
2104.504 |
REMOVE BITUMINOUS PAVEMENT |
SQ YD |
11,266 |
30 |
2104.504 |
REMOVE CONCRETE DRIVEWAY PAVEMENT |
SQ YD |
280 |
31 |
2104.504 |
REMOVE CONCRETE PAVEMENT |
SQ YD |
2,046 |
32 |
2104.518 |
REMOVE BITUMINOUS WALK |
SQ FT |
1,106 |
33 |
2104.518 |
REMOVE CONCRETE WALK |
SQ FT |
20,308 |
34 |
2105.607 |
CONTAMINATED SOIL EXCAVATION |
CU YD |
200 |
35 |
2105.607 |
HAULING CONTAMINATED SOIL |
CU YD |
200 |
36 |
2105.607 |
STOCKPILE CONTAMINATED SOIL |
CU YD |
200 |
37 |
2106.507 |
COMMON EMBANKMENT (CV) (P) |
CU YD |
892 |
38 |
2106.507 |
EXCAVATION - COMMON (P) |
CU YD |
9,380 |
39 |
2106.507 |
EXCAVATION - SUBGRADE (P) |
CU YD |
9,009 |
40 |
2106.507 |
SELECT GRANULAR EMBANKMENT (CV) (P) |
CU YD |
9,009 |
41 |
2118.507 |
AGGREGATE SURFACING (CV) CLASS 1 |
CU YD |
3 |
42 |
2211.507 |
AGGREGATE BASE (CV) CLASS 5 (P) |
CU YD |
5,806 |
43 |
2231.509 |
BITUMINOUS PATCHING MIXTURE |
TON |
153 |
44 |
2301.502 |
DOWEL BAR |
EACH |
1,113 |
45 |
2301.504 |
CONCRETE PAVEMENT 9.0" |
SQ YD |
2,058 |
46 |
2301.508 |
SUPPLEMENTAL PAVEMENT REINFORCEMENT |
POUND |
1,305 |
47 |
2301.602 |
DRILL AND GROUT DOWEL BAR (EPOXY COATED) |
EACH |
147 |
48 |
2301.602 |
DRILL AND GROUT REINF BAR (EPOXY COATED) |
EACH |
136 |
49 |
2360.504 |
TYPE SP 9.5 WEARING COURSE MIXTURE (2,B) 4.0" THICK |
SQ YD |
75 |
50 |
2360.509 |
TYPE SP 12.5 NON WEARING COURSE MIXTURE (4,B) |
TON |
1,170 |
51 |
2360.509 |
TYPE SP 9.5 WEARING COURSE MIXTURE (4,E) |
TON |
2,796 |
52 |
2411.502 |
CONCRETE STAIRWAY |
EACH |
1 |
53 |
2502.503 |
4" PERF PE PIPE DRAIN |
LIN FT |
2,560 |
54 |
2503.503 |
12" RC PIPE SEWER DESIGN 3006 CLASS V |
LIN FT |
40 |
55 |
2503.503 |
15" RC PIPE SEWER DESIGN 3006 CLASS V |
LIN FT |
899 |
56 |
2503.503 |
18" RC PIPE SEWER DESIGN 3006 CLASS V |
LIN FT |
509 |
57 |
2503.503 |
24" RC PIPE SEWER DESIGN 3006 CLASS III |
LIN FT |
163 |
58 |
2503.503 |
30" RC PIPE SEWER DESIGN 3006 CLASS III |
LIN FT |
195 |
59 |
2503.602 |
CONNECT INTO EXISTING DRAINAGE STRUCTURE |
EACH |
2 |
60 |
2503.602 |
CONNECT TO EXISTING STORM SEWER |
EACH |
4 |
61 |
2503.602 |
CONSTRUCT BULKHEAD |
EACH |
4 |
62 |
2503.603 |
PLUG FILL AND ABANDON PIPE SEWER |
LIN FT |
130 |
63 |
2504.602 |
ADJUST GATE VALVE AND BOX |
EACH |
5 |
64 |
2504.602 |
ADJUST HYDRANT |
EACH |
1 |
65 |
2506.502 |
ADJUST FRAME AND RING CASTING |
EACH |
1 |
66 |
2506.502 |
CASTING ASSEMBLY |
EACH |
36 |
67 |
2506.502 |
CONSTRUCT DRAINAGE STRUCTURE DESIGN SPECIAL 1 |
EACH |
5 |
68 |
2506.503 |
CONSTRUCT DRAINAGE STRUCTURE DESIGN 48-4020 |
LIN FT |
103.8 |
69 |
2506.503 |
CONSTRUCT DRAINAGE STRUCTURE DESIGN 60-4020 |
LIN FT |
47 |
70 |
2506.503 |
CONSTRUCT DRAINAGE STRUCTURE DESIGN SD-48 |
LIN FT |
13.9 |
71 |
2506.602 |
ADJUST FRAME AND RING CASTING (SPECIAL) |
EACH |
1 |
72 |
2506.602 |
CASTING ASSEMBLY SPECIAL |
EACH |
3 |
73 |
2506.602 |
RECONSTRUCT DRAINAGE STRUCTURE SPECIAL |
EACH |
3 |
74 |
2506.602 |
SEAL MANHOLE |
EACH |
4 |
75 |
2521.518 |
3" BITUMINOUS WALK |
SQ FT |
1,312 |
76 |
2521.518 |
6" CONCRETE WALK |
SQ FT |
9,266 |
77 |
2521.518 |
6" CONCRETE WALK SPECIAL |
SQ FT |
9,893 |
78 |
2521.602 |
DRILL AND GROUT REINF BAR (EPOXY COATED) |
EACH |
298 |
79 |
2521.618 |
CONCRETE CURB RAMP WALK |
SQ FT |
3,382 |
80 |
2531.503 |
CONCRETE CURB AND GUTTER DESIGN B424 |
LIN FT |
36 |
81 |
2531.503 |
CONCRETE CURB AND GUTTER DESIGN B618 |
LIN FT |
69 |
82 |
2531.503 |
CONCRETE CURB AND GUTTER DESIGN B624 |
LIN FT |
4,783 |
83 |
2531.504 |
6" CONCRETE DRIVEWAY PAVEMENT |
SQ YD |
189 |
84 |
2531.504 |
8" CONCRETE DRIVEWAY PAVEMENT |
SQ YD |
88 |
85 |
2531.618 |
TRUNCATED DOMES |
SQ FT |
440 |
86 |
2533.503 |
PORTABLE PRECAST CONCRETE BARRIER DESIGN 8337 |
LIN FT |
560 |
87 |
2533.503 |
RELOCATE PORTABLE PRECAST CONCRETE BARRIER DESIGN 8337 |
LIN FT |
850 |
88 |
2540.602 |
MAIL BOX SUPPORT |
EACH |
2 |
89 |
2540.603 |
INSTALL RETAINING WALL |
LIN FT |
25 |
90 |
2563.601 |
ALTERNATE PEDESTRIAN ROUTE |
LUMP SUM |
1 |
91 |
2563.601 |
TRAFFIC CONTROL |
LUMP SUM |
1 |
92 |
2563.615 |
RELOCATE TEMPORARY IMPACT ATTENUATOR |
ASSEMBLY |
5 |
93 |
2563.615 |
TEMPORARY IMPACT ATTENUATOR |
ASSEMBLY |
2 |
94 |
2564.502 |
INSTALL SIGN |
EACH |
3 |
95 |
2564.602 |
DELINEATOR / MARKER PANEL |
EACH |
5 |
96 |
2564.618 |
SIGN |
SQ FT |
242 |
97 |
2565.501 |
EMERGENCY VEHICLE PREEMPTION SYSTEM A |
LUMP SUM |
1 |
98 |
2565.501 |
EMERGENCY VEHICLE PREEMPTION SYSTEM B |
LUMP SUM |
1 |
99 |
2565.501 |
TRAFFIC CONTROL INTERCONNECT |
LUMP SUM |
1 |
100 |
2565.516 |
TRAFFIC CONTROL SIGNAL SYSTEM A |
SYSTEM |
1 |
101 |
2565.516 |
TRAFFIC CONTROL SIGNAL SYSTEM B |
SYSTEM |
1 |
102 |
2565.616 |
TEMPORARY SIGNAL SYSTEM A |
SYSTEM |
1 |
103 |
2565.616 |
TEMPORARY SIGNAL SYSTEM B |
SYSTEM |
1 |
104 |
2573.501 |
EROSION CONTROL SUPERVISOR |
LUMP SUM |
1 |
105 |
2573.501 |
STABILIZED CONSTRUCTION EXIT |
LUMP SUM |
1 |
106 |
2573.502 |
STORM DRAIN INLET PROTECTION |
EACH |
69 |
107 |
2573.503 |
SILT FENCE, TYPE MS |
LIN FT |
1,845 |
108 |
2574.507 |
BOULEVARD TOPSOIL BORROW |
CU YD |
90 |
109 |
2574.508 |
FERTILIZER TYPE 3 |
POUND |
453 |
110 |
2575.504 |
SODDING TYPE LAWN |
SQ YD |
2,433 |
111 |
2575.505 |
SEEDING |
ACRE |
1 |
112 |
2575.508 |
HYDRAULIC STABILIZED FIBER MATRIX |
POUND |
3,300 |
113 |
2575.508 |
SEED MIXTURE 25-131 |
POUND |
220 |
114 |
2575.523 |
RAPID STABILIZATION METHOD 3 |
M GALLON |
21 |
115 |
2582.503 |
24" SOLID LINE MULTI-COMPONENT GROUND IN (WR) |
LIN FT |
197 |
116 |
2582.503 |
24" SOLID LINE PAINT (WR) |
LIN FT |
101 |
117 |
2582.503 |
4" BROKEN LINE MULTI-COMPONENT GROUND IN (WR) |
LIN FT |
406 |
118 |
2582.503 |
4" BROKEN LINE PREFORM TAPE GROUND IN (WR) CONTRAST |
LIN FT |
100 |
119 |
2582.503 |
4" DOTTED LINE MULTI-COMPONENT GROUND IN (WR) |
LIN FT |
45 |
120 |
2582.503 |
4" DOUBLE SOLID LINE MULTI-COMPONENT GROUND IN (WR) |
LIN FT |
611 |
121 |
2582.503 |
4" SOLID LINE MULTI-COMPONENT GROUND IN (WR) |
LIN FT |
1,957 |
122 |
2582.503 |
6" BROKEN LINE PAINT (WR) |
LIN FT |
45 |
123 |
2582.503 |
6" DOUBLE SOLID LINE PAINT (WR) |
LIN FT |
4,582 |
124 |
2582.503 |
6" SOLID LINE MULTI-COMPONENT GROUND IN (WR) |
LIN FT |
3,549 |
125 |
2582.503 |
6" SOLID LINE PAINT (WR) |
LIN FT |
14,461 |
126 |
2582.503 |
6" SOLID LINE PREFORM TAPE GROUND IN (WR) CONTRAST |
LIN FT |
613 |
127 |
2582.518 |
CROSSWALK PREFORM THERMOPLASTIC GROUND IN |
SQ FT |
2,160 |
128 |
2582.518 |
PAVEMENT MESSAGE PAINT |
SQ FT |
460 |
129 |
2582.518 |
PAVEMENT MESSAGE PREFORM THERMOPLASTIC GROUND IN |
SQ FT |
155 |
130 |
2582.518 |
PAVEMENT MESSAGE PREFORM THERMOPLASTIC GROUND IN CONTRAST |
SQ FT |
62 |