Line |
Item Number |
Description |
Units |
Quantity |
053-606-020 53538 Bridge Replacement |
1 |
2011.601 |
CONSTRUCTION SURVEYING |
LUMP SUM |
1 |
2 |
2021.501 |
MOBILIZATION |
LUMP SUM |
1 |
3 |
2104.503 |
REMOVE PIPE CULVERTS |
LIN FT |
96 |
4 |
2106.507 |
SELECT GRANULAR EMBANKMENT (CV) |
C Y |
1,674 |
5 |
2106.507 |
EXCAVATION - COMMON |
CU YD |
2,065 |
6 |
2106.507 |
COMMON EMBANKMENT (CV) |
CU YD |
3,529 |
7 |
2112.519 |
SUBGRADE PREPARATION |
ROAD STA |
10 |
8 |
2211.509 |
AGGREGATE BASE CLASS 5 |
TON |
1,413 |
9 |
2221.509 |
SHOULDER BASE AGGREGATE CLASS 1 |
TON |
221 |
10 |
2232.504 |
MILL BITUMINOUS SURFACE |
S Y |
3,173 |
11 |
2360.509 |
TYPE SP 12.5 WEARING COURSE MIX (2,B) |
TON |
1,297 |
13 |
2401.503 |
TYPE F (TL-4) BARRIER CONCRETE (3S52) |
LIN FT |
255 |
14 |
2401.507 |
STRUCTURAL CONCRETE (3B52) |
CU YD |
86 |
15 |
2401.508 |
REINFORCEMENT BARS (EPOXY COATED) |
POUND |
60,290 |
16 |
2401.508 |
REINFORCEMENT BARS (STAINLESS-75KSI) |
POUND |
720 |
17 |
2401.518 |
BRIDGE SLAB CONCRETE (3YHPC-M) |
SQ FT |
3,658 |
18 |
2401.601 |
STRUCTURE EXCAVATION |
LUMP SUM |
1 |
19 |
2401.601 |
SLOPE PREPARATION |
LUMP SUM |
1 |
20 |
2402.502 |
FLOOR DRAIN TYPE B702 |
EACH |
4 |
21 |
2406.504 |
BRIDGE APPROACH PANELS |
SQ YD |
152 |
22 |
2442.501 |
REMOVE EXISTING BRIDGE |
LUMP SUM |
1 |
23 |
2451.607 |
STRUCTURAL BACKFILL (CV) |
CU YD |
792 |
24 |
2452.502 |
C-I-P CONC TEST PILE 95 FT LONG 12" |
EACH |
2 |
25 |
2452.502 |
C-I-P CONC TEST PILE 100 FT LONG 16" |
EACH |
2 |
26 |
2452.502 |
PILE POINTS 12" |
EACH |
8 |
27 |
2452.502 |
PILE POINTS 16" |
EACH |
10 |
28 |
2452.503 |
C-I-P CONCRETE PILING 12" |
LIN FT |
510 |
29 |
2452.503 |
C-I-P CONCRETE PILING 16" |
LIN FT |
720 |
30 |
2501.502 |
15" GS PIPE APRON |
EACH |
6 |
31 |
2501.503 |
15" CS PIPE CULVERT |
LIN FT |
230 |
32 |
2502.501 |
DRAINAGE SYSTEM TYPE (B910) |
LUMP SUM |
1 |
34 |
2511.504 |
GEOTEXTILE FILTER TYPE 7 |
SQ YD |
635 |
35 |
2511.509 |
RANDOM RIPRAP CLASS III |
TON |
630 |
36 |
2554.502 |
END TREATMENT-TANGENT TERMINAL |
EACH |
4 |
37 |
2554.503 |
TRAFFIC BARRIER DESIGN TRANS TYPE 31 |
L F |
150 |
38 |
2554.503 |
TRAFFIC BARRIER DESIGN TYPE 31 |
L F |
100 |
39 |
2563.601 |
TRAFFIC CONTROL |
LUMP SUM |
1 |
40 |
2573.501 |
EROSION CONTROL SUPERVISOR |
LUMP SUM |
1 |
41 |
2573.503 |
SILT FENCE, TYPE MS |
LIN FT |
2,111 |
42 |
2573.503 |
FLOTATION SILT CURTAIN TYPE MOVING WATER |
LIN FT |
250 |
43 |
2573.503 |
SEDIMENT CONTROL LOG TYPE WOOD FIBER |
LIN FT |
278 |
44 |
2575.501 |
TURF ESTABLISHMENT |
LUMP SUM |
1 |
45 |
2575.504 |
ROLLED EROSION PREVENTION CATEGORY 25 |
SQ YD |
4,499 |
46 |
2575.504 |
ROLLED EROSION PREVENTION CATEGORY 74 |
SQ YD |
95 |
47 |
2575.523 |
RAPID STABILIZATION METHOD 3 |
M GALLON |
43 |
48 |
2582.503 |
4" SOLID LINE PAINT |
LIN FT |
2,200 |
49 |
2582.503 |
4" BROKEN LINE PAINT |
LIN FT |
220 |
053-619-027 53537 Bridge Replacement |
1 |
2011.601 |
CONSTRUCTION SURVEYING |
LUMP SUM |
1 |
2 |
2021.501 |
MOBILIZATION |
LUMP SUM |
1 |
3 |
2106.507 |
SELECT GRANULAR EMBANKMENT (CV) |
C Y |
1,002 |
4 |
2106.507 |
EXCAVATION - COMMON |
CU YD |
1,816 |
5 |
2106.507 |
COMMON EMBANKMENT (CV) |
CU YD |
1,948 |
6 |
2112.519 |
SUBGRADE PREPARATION |
ROAD STA |
5 |
7 |
2211.509 |
AGGREGATE BASE CLASS 5 |
TON |
988 |
8 |
2221.509 |
SHOULDER BASE AGGREGATE CLASS 1 |
TON |
36 |
9 |
2232.504 |
MILL BITUMINOUS SURFACE |
S Y |
2,196 |
10 |
2360.509 |
TYPE SP 12.5 WEARING COURSE MIX (2,B) |
TON |
840 |
12 |
2401.503 |
TYPE F (TL-4) BARRIER CONCRETE (3S52) |
LIN FT |
278 |
13 |
2401.507 |
STRUCTURAL CONCRETE (3B52) |
CU YD |
86 |
14 |
2401.508 |
REINFORCEMENT BARS (EPOXY COATED) |
POUND |
72,540 |
15 |
2401.508 |
REINFORCEMENT BARS (STAINLESS-75KSI) |
POUND |
720 |
16 |
2401.601 |
STRUCTURE EXCAVATION |
LUMP SUM |
1 |
17 |
2401.601 |
SLOPE PREPARATION |
LUMP SUM |
1 |
18 |
2401.618 |
BRIDGE SLAB CONCRETE (3YHPC-M) |
SQ FT |
4,078 |
19 |
2402.502 |
FLOOR DRAIN TYPE B702 |
EACH |
4 |
20 |
2406.504 |
BRIDGE APPROACH PANELS |
SQ YD |
152 |
21 |
2442.501 |
REMOVE EXISTING BRIDGE |
LUMP SUM |
1 |
22 |
2451.607 |
STRUCTURAL BACKFILL (CV) |
CU YD |
802 |
23 |
2452.502 |
C-I-P CONC TEST PILE 90 FT LONG 12" |
EACH |
2 |
24 |
2452.502 |
C-I-P CONC TEST PILE 95 FT LONG 16" |
EACH |
2 |
25 |
2452.502 |
PILE POINTS 12" |
EACH |
8 |
26 |
2452.502 |
PILE POINTS 16" |
EACH |
10 |
27 |
2452.503 |
C-I-P CONCRETE PILING 12" |
LIN FT |
480 |
28 |
2452.503 |
C-I-P CONCRETE PILING 16" |
LIN FT |
680 |
29 |
2502.501 |
DRAINAGE SYSTEM TYPE (B910) |
LUMP SUM |
1 |
30 |
2511.504 |
GEOTEXTILE FILTER TYPE 7 |
SQ YD |
930 |
31 |
2511.509 |
RANDOM RIPRAP CLASS V |
TON |
1,485 |
32 |
2554.502 |
END TREATMENT-TANGENT TERMINAL |
EACH |
4 |
33 |
2554.503 |
TRAFFIC BARRIER DESIGN TYPE 31 |
LIN FT |
100 |
34 |
2554.503 |
TRAFFIC BARRIER DESIGN TRANS TYPE 31 |
LIN FT |
150 |
35 |
2563.601 |
TRAFFIC CONTROL |
LUMP SUM |
1 |
36 |
2573.501 |
EROSION CONTROL SUPERVISOR |
LUMP SUM |
1 |
37 |
2573.503 |
SILT FENCE, TYPE MS |
LIN FT |
1,321 |
38 |
2573.503 |
FLOTATION SILT CURTAIN TYPE MOVING WATER |
LIN FT |
300 |
39 |
2573.503 |
SEDIMENT CONTROL LOG TYPE WOOD CHIP |
LIN FT |
120 |
40 |
2575.501 |
TURF ESTABLISHMENT |
LUMP SUM |
1 |
41 |
2575.504 |
ROLLED EROSION PREVENTION CATEGORY 25 |
SQ YD |
3,869 |
42 |
2575.504 |
ROLLED EROSION PREVENTION CATEGORY 74 |
SQ YD |
142 |
43 |
2575.523 |
RAPID STABILIZATION METHOD 3 |
M GALLON |
33 |
44 |
2582.503 |
4" SOLID LINE PAINT |
LIN FT |
200 |
45 |
2582.503 |
6" SOLID LINE PAINT |
LIN FT |
1,098 |
46 |
2582.503 |
4" BROKEN LINE PAINT |
LIN FT |
110 |