Line |
Item Number |
Description |
Units |
Quantity |
SAP 060-609-022 CSAH 9 Box Culvert - Bridge 60L55 |
9 |
2412.502 |
14X14 PRECAST CONCRETE BOX CULVERT END SECTION (TYPE I) |
EACH |
6 |
10 |
2412.503/14140 |
14X14 PRECAST CONCRETE BOX CULVERT |
L F |
119 |
12 |
2451.507/00060 |
GRANULAR BACKFILL (LV) |
C Y |
2,515 |
14 |
2511.507/00014 |
RANDOM RIPRAP CLASS III |
C Y |
208 |
15 |
2520.507/00010 |
LEAN MIX BACKFILL (P) |
C Y |
70 |
16 |
2563.601/00010 |
TRAFFIC CONTROL |
LS |
0.5 |
22 |
2412.603 |
INSTALL PRECAST BOX CULVERT |
LIN FT |
115 |
SAP 060-609-022 CSAH 9 Box Culvert - CSAH 9 |
1 |
2101.502 |
CLEARING |
EACH |
1 |
2 |
2101.502 |
GRUBBING |
EACH |
1 |
3 |
2104.503/00440 |
REMOVE GUARDRAIL |
L F |
307 |
4 |
2104.504/00120 |
REMOVE BITUMINOUS PAVEMENT |
S Y |
340 |
5 |
2108.504 |
GEOGRID TYPE 2 |
SQ YD |
667 |
6 |
2211.509/00080 |
AGGREGATE BASE CLASS 5 MOD |
TON |
660 |
7 |
2221.509/00090 |
SHOULDER BASE AGGREGATE CLASS 5 MOD |
TON |
105 |
8 |
2360.509/12200 |
TYPE SP 9.5 WEARING COURSE MIX (2,B) |
TON |
160 |
11 |
2442.501/00010 |
REMOVE EXISTING BRIDGE |
LS |
1 |
13 |
2451.507/00060 |
GRANULAR BACKFILL (LV) |
C Y |
990 |
17 |
2563.601/00010 |
TRAFFIC CONTROL |
LS |
0.5 |
18 |
2573.503/00060 |
SEDIMENT CONTROL LOG TYPE STRAW |
L F |
200 |
19 |
2573.503/00021 |
SILT FENCE, TYPE PA |
L F |
200 |
20 |
2575.501/00020 |
TURF ESTABLISHMENT |
LS |
1 |
21 |
2575.504 |
ROLLED EROSION PREVENTION CATEGORY 10 |
SQ YD |
700 |
SAP 060-621-015 CSAH 21 Box Culvert - Bridge 60L56 |
8 |
2412.502/14100 |
14X10 PRECAST CONCRETE BOX CULV END SECT (TYPE I) |
EACH |
6 |
9 |
2412.503/14100 |
14X10 PRECAST CONCRETE BOX CULVERT |
L F |
162 |
10 |
2451.507/00080 |
GRANULAR BACKFILL (CV) (P) |
C Y |
1,050 |
13 |
2511.507/00014 |
RANDOM RIPRAP CLASS III |
C Y |
199 |
14 |
2520.507/00010 |
LEAN MIX BACKFILL (P) |
C Y |
37 |
15 |
2563.601/00010 |
TRAFFIC CONTROL |
LS |
0.5 |
SAP 060-621-015 CSAH 21 Box Culvert - CSAH 21 |
1 |
2104.503/00260 |
REMOVE CONCRETE CULVERT |
L F |
276 |
2 |
2104.504/00120 |
REMOVE BITUMINOUS PAVEMENT |
S Y |
3,800 |
3 |
2106.507/00010 |
EXCAVATION - COMMON |
C Y |
3,933 |
4 |
2106.507/00130 |
COMMON EMBANKMENT (CV) |
C Y |
2,822 |
5 |
2108.504 |
GEOGRID TYPE 2 |
SQ YD |
4,445 |
6 |
2211.509/00080 |
AGGREGATE BASE CLASS 5 MOD |
TON |
2,600 |
7 |
2360.509/12200 |
TYPE SP 9.5 WEARING COURSE MIX (2,B) |
TON |
1,110 |
11 |
2501.502/05018 |
18" RC PIPE APRON |
EACH |
4 |
12 |
2501.503/13182 |
18" RC PIPE CULVERT |
L F |
106 |
16 |
2563.601/00010 |
TRAFFIC CONTROL |
LS |
0.5 |
17 |
2573.503/00060 |
SEDIMENT CONTROL LOG TYPE STRAW |
L F |
400 |
18 |
2573.503/00021 |
SILT FENCE, TYPE PA |
L F |
400 |
19 |
2575.501/00020 |
TURF ESTABLISHMENT |
LS |
1 |
20 |
2575.504 |
ROLLED EROSION PREVENTION CATEGORY 10 |
SQ YD |
1,800 |
21 |
2582.503/10104 |
4" SOLID LINE PAINT |
L F |
3,450 |
22 |
2582.503/10204 |
4" BROKEN LINE PAINT |
L F |
270 |