Line |
Item Number |
Description |
Units |
Quantity |
Addendum #1 |
154 |
2582.518 |
PAVT MSSG PREF THERMO GR IN |
S F |
109 |
155 |
2582.518 |
CROSSWALK PREF THERMO GR IN |
S F |
1,395 |
Base Bid |
1 |
2011.610 |
UNDERGROUND UTILITY EXPLORATION |
HOUR |
30 |
2 |
2021.501 |
MOBILIZATION |
LS |
1 |
3 |
2031.502 |
FIELD OFFICE |
EACH |
1 |
4 |
2041.610 |
TRAINEES |
HOUR |
2,000 |
5 |
2101.502 |
GRUBBING |
EACH |
65 |
6 |
2102.503 |
PAVEMENT MARKING REMOVAL |
L F |
60 |
7 |
2104.502 |
REMOVE CONCRETE STEPS |
EACH |
12 |
8 |
2104.502 |
REMOVE PLANTER |
EACH |
2 |
9 |
2104.502 |
REMOVE MANHOLE OR CATCH BASIN |
EACH |
74 |
10 |
2104.502 |
REMOVE GATE VALVE AND BOX |
EACH |
24 |
11 |
2104.502 |
REMOVE CURB STOP AND BOX |
EACH |
27 |
12 |
2104.502 |
REMOVE HYDRANT |
EACH |
11 |
13 |
2104.502 |
REMOVE SIGN |
EACH |
43 |
14 |
2104.502 |
REMOVE HANDHOLE |
EACH |
1 |
15 |
2104.502 |
REMOVE LIGHT FOUNDATION |
EACH |
40 |
16 |
2104.502 |
REMOVE SIGN PANEL |
EACH |
27 |
17 |
2104.502 |
REMOVE BENCH |
EACH |
1 |
18 |
2104.502 |
SALVAGE BOULDER |
EACH |
8 |
19 |
2104.502 |
SALVAGE LIGHTING UNIT |
EACH |
40 |
20 |
2104.502 |
SALVAGE SERVICE CABINET |
EACH |
1 |
21 |
2104.502 |
SALVAGE SIGN |
EACH |
2 |
22 |
2104.502 |
SALVAGE SIGN PANEL |
EACH |
20 |
23 |
2104.502 |
SALVAGE MAIL BOX SUPPORT |
EACH |
6 |
24 |
2104.502 |
ABANDON MANHOLE |
EACH |
1 |
25 |
2104.503 |
SAWING CONCRETE PAVEMENT (FULL DEPTH) |
L F |
1,070 |
26 |
2104.503 |
SAWING BITUMINOUS PAVEMENT (FULL DEPTH) |
L F |
1,190 |
27 |
2104.503 |
REMOVE WATER MAIN |
L F |
3,784 |
28 |
2104.503 |
REMOVE SEWER PIPE (STORM) |
L F |
1,874 |
29 |
2104.503 |
REMOVE SEWER PIPE (SANITARY) |
L F |
87 |
30 |
2104.503 |
REMOVE CURB AND GUTTER |
L F |
12,400 |
31 |
2104.503 |
REMOVE RETAINING WALL |
L F |
180 |
32 |
2104.503 |
REMOVE WATER SERVICE PIPE |
L F |
1,070 |
33 |
2104.503 |
REMOVE DIRECT BURIED LIGHTING CABLE |
L F |
11,300 |
34 |
2104.503 |
SALVAGE FENCE |
L F |
340 |
35 |
2104.503 |
SALVAGE RETAINING WALL |
L F |
180 |
36 |
2104.504 |
REMOVE CONCRETE WALK |
S Y |
2,760 |
37 |
2104.504 |
REMOVE CONCRETE DRIVEWAY PAVEMENT |
S Y |
2,250 |
38 |
2104.504 |
REMOVE BITUMINOUS DRIVEWAY PAVEMENT |
S Y |
975 |
39 |
2104.504 |
REMOVE BITUMINOUS PAVEMENT |
S Y |
28,750 |
40 |
2104.602 |
SALVAGE SIGN SPECIAL |
EACH |
13 |
41 |
2104.603 |
ABANDON PIPE SEWER |
L F |
133 |
42 |
2106.507 |
EXCAVATION - COMMON (P) |
C Y |
10,595 |
43 |
2106.507 |
GRANULAR EMBANKMENT (CV) |
C Y |
100 |
44 |
2106.507 |
COMMON EMBANKMENT (CV) (P) |
C Y |
708 |
45 |
2106.601 |
DEWATERING |
LS |
1 |
46 |
2106.607 |
HAUL AND DISPOSE OF CONTAMINATED MATERIAL |
C Y |
1,200 |
47 |
2123.610 |
STREET SWEEPER (WITH PICKUP BROOM) |
HOUR |
150 |
48 |
2130.523 |
WATER |
MGAL |
150 |
49 |
2211.507 |
AGGREGATE BASE (CV) CLASS 5 (P) |
C Y |
10,290 |
50 |
2301.504 |
CONCRETE PAVEMENT 8.0" |
S Y |
1,080 |
51 |
2301.602 |
DRILL AND GROUT DOWEL BAR (EPOXY COATED) |
EACH |
4,050 |
52 |
2302.502 |
DRILL & GROUT REINF BAR (EPOXY COATED) |
EACH |
1,000 |
53 |
2331.603 |
JOINT ADHESIVE |
L F |
7,000 |
54 |
2360.509 |
TYPE SP 9.5 WEARING COURSE MIXTURE (2,C) |
TON |
160 |
55 |
2360.509 |
TYPE SP 9.5 WEARING COURSE MIXTURE (3,C) |
TON |
2,345 |
56 |
2360.509 |
TYPE SP 12.5 NON WEARING COURSE MIXTURE (3,B) |
TON |
2,345 |
57 |
2360.509 |
TYPE SP 12.5 WEARING COURSE MIXTURE (3,C) |
TON |
2,345 |
58 |
2411.603 |
INSTALL RETAINING WALL |
L F |
180 |
59 |
2411.607 |
CONCRETE STEPS |
C Y |
2 |
60 |
2411.618 |
MODULAR BLOCK RETAINING WALL |
S F |
1,175 |
61 |
2503.503 |
8" PVC PIPE SEWER |
L F |
20 |
62 |
2503.503 |
12" RC PIPE SEWER DESIGN 3006 CLASS V |
L F |
218 |
63 |
2503.503 |
15" RC PIPE SEWER DESIGN 3006 CLASS V |
L F |
1,993 |
64 |
2503.503 |
18" RC PIPE SEWER DESIGN 3006 CLASS V |
L F |
117 |
65 |
2503.503 |
36" RC PIPE SEWER DESIGN 3006 CLASS V |
L F |
83 |
66 |
2503.602 |
CONNECT TO EXISTING SANITARY SEWER |
EACH |
1 |
67 |
2503.602 |
CONNECT TO EXISTING STORM SEWER |
EACH |
48 |
68 |
2504.601 |
TEMPORARY WATER SERVICE |
LS |
1 |
69 |
2504.602 |
CONNECT TO EXISTING WATER MAIN |
EACH |
23 |
70 |
2504.602 |
HYDRANT |
EACH |
9 |
71 |
2504.602 |
ADJUST GATE VALVE AND BOX |
EACH |
14 |
72 |
2504.602 |
ADJUST WATER MANHOLES |
EACH |
3 |
73 |
2504.602 |
1" CORPORATION STOP |
EACH |
29 |
74 |
2504.602 |
6" GATE VALVE AND BOX |
EACH |
9 |
75 |
2504.602 |
12" GATE VALVE AND BOX |
EACH |
19 |
76 |
2504.602 |
ADJUST CURB STOP |
EACH |
11 |
77 |
2504.602 |
1" CURB STOP |
EACH |
29 |
78 |
2504.603 |
WATERMAIN INSULATION |
L F |
100 |
79 |
2504.603 |
1" TYPE K COPPER PIPE |
L F |
831 |
80 |
2504.603 |
1" TYPE K COPPER PIPE (SPECIAL) |
LF |
265 |
81 |
2504.603 |
6" WATERMAIN DUCTILE IRON CL 52 |
L F |
102 |
82 |
2504.603 |
12" WATERMAIN DUCTILE IRON CL 52 |
L F |
3,630 |
83 |
2504.608 |
DUCTILE IRON FITTINGS |
LB |
3,950 |
84 |
2506.502 |
CASTING ASSEMBLY |
EACH |
90 |
85 |
2506.503 |
CONSTRUCT DRAINAGE STRUCTURE DESIGN F |
L F |
13.6 |
86 |
2506.503 |
CONSTRUCT DRAINAGE STRUCTURE DESIGN SPECIAL |
L F |
157.4 |
87 |
2506.503 |
CONSTRUCT DRAINAGE STRUCTURE DESIGN 48-4020 |
L F |
182.7 |
88 |
2506.503 |
CONSTRUCT DRAINAGE STRUCTURE DESIGN 60-4020 |
L F |
84.2 |
89 |
2506.602 |
ADJUST FRAME AND RING CASTING (SPECIAL) |
EACH |
45 |
90 |
2511.602 |
PLACE BOULDER |
EACH |
8 |
91 |
2521.518 |
4" CONCRETE WALK |
S F |
9,100 |
92 |
2521.518 |
6" CONCRETE WALK |
S F |
32,000 |
93 |
2521.518 |
6" CONCRETE WALK SPECIAL |
S F |
54,300 |
94 |
2521.618 |
CONCRETE WALK |
S F |
7,350 |
95 |
2531.503 |
CONCRETE CURB AND GUTTER DESIGN SPECIAL |
L F |
4,640 |
96 |
2531.503 |
CONCRETE CURB AND GUTTER DESIGN B612 |
L F |
540 |
97 |
2531.503 |
CONCRETE CURB AND GUTTER DESIGN B618 |
L F |
5,550 |
98 |
2531.503 |
CONCRETE CURB DESIGN B6 |
L F |
1,210 |
99 |
2531.504 |
6" CONCRETE DRIVEWAY PAVEMENT |
S Y |
2,450 |
100 |
2531.504 |
8" CONCRETE DRIVEWAY PAVEMENT |
S Y |
205 |
101 |
2531.603 |
CONCRETE CURB DESIGN V |
L F |
165 |
102 |
2531.604 |
8" CONCRETE DRIVEWAY PAVEMENT WITH INTEGRAL COLORING |
S Y |
95 |
103 |
2531.604 |
6" CONCRETE DRIVEWAY PAVEMENT WITH INTEGRAL COLORING |
S Y |
1,105 |
104 |
2531.618 |
TRUNCATED DOMES |
S F |
690 |
105 |
2533.503 |
PORTABLE PRECAST CONCRETE BARRIER DESIGN 8337 |
L F |
180 |
106 |
2540.602 |
LANDSCAPE MONUMENT |
EACH |
10 |
107 |
2540.602 |
RELOCATE MAIL BOX SUPPORT |
EACH |
6 |
108 |
2545.502 |
LIGHTING UNIT TYPE SPECIAL |
EACH |
5 |
109 |
2545.502 |
LIGHT FOUNDATION DESIGN E MODIFIED |
EACH |
45 |
110 |
2545.502 |
SERVICE CABINET |
EACH |
1 |
111 |
2545.502 |
EQUIPMENT PAD |
EACH |
2 |
112 |
2545.502 |
HANDHOLE |
EACH |
1 |
113 |
2545.503 |
2" RIGID STEEL CONDUIT |
L F |
195 |
114 |
2545.503 |
2" NON-METALLIC CONDUIT |
L F |
12,570 |
115 |
2545.503 |
UNDERGROUND WIRE 1/C 2 AWG |
L F |
585 |
116 |
2545.503 |
UNDERGROUND WIRE 1/C 6 AWG |
L F |
48,485 |
117 |
2545.503 |
UNDERGROUND WIRE 1/C 14 AWG |
L F |
10,775 |
118 |
2545.602 |
INSTALL LIGHTING UNIT |
EACH |
40 |
119 |
2545.602 |
INSTALL SERVICE CABINET |
EACH |
1 |
120 |
2557.503 |
WIRE FENCE DESIGN 60V-9322 |
L F |
165 |
121 |
2557.603 |
INSTALL FENCE |
L F |
340 |
122 |
2563.601 |
TRAFFIC CONTROL |
LS |
1 |
123 |
2563.601 |
ALTERNATE PEDESTRIAN ROUTE |
LS |
1 |
124 |
2564.502 |
INSTALL SIGN PANEL |
EACH |
13 |
125 |
2564.602 |
INSTALL SIGN |
EACH |
9 |
126 |
2564.602 |
INSTALL SIGN SPECIAL |
EACH |
15 |
127 |
2564.602 |
DELINEATOR / MARKER PANEL |
EACH |
6 |
128 |
2564.618 |
SIGN |
S F |
306 |
129 |
2564.618 |
SIGN PANEL |
S F |
99 |
130 |
2565.616 |
PEDESTRIAN CROSSWALK FLASHER SYSTEM |
SYS |
3 |
131 |
2565.616 |
REVISE SIGNAL SYSTEM A |
SYS |
1 |
132 |
2565.616 |
REVISE SIGNAL SYSTEM B |
SYS |
1 |
133 |
2571.502 |
DECIDUOUS TREE 2" CAL CONT |
EACH |
83 |
134 |
2571.502 |
DECIDUOUS SHRUB NO 2 CONT |
EACH |
28 |
135 |
2572.503 |
TEMPORARY FENCE |
L F |
8,300 |
136 |
2572.503 |
CLEAN ROOT CUTTING |
L F |
1,500 |
137 |
2573.501 |
STABILIZED CONSTRUCTION EXIT |
LS |
1 |
138 |
2573.501 |
EROSION CONTROL SUPERVISOR |
LS |
1 |
139 |
2573.502 |
STORM DRAIN INLET PROTECTION |
EACH |
87 |
140 |
2573.503 |
SILT FENCE, TYPE MS |
L F |
1,050 |
141 |
2573.503 |
SEDIMENT CONTROL LOG TYPE WOOD FIBER |
L F |
11,200 |
142 |
2574.507 |
COMMON TOPSOIL BORROW |
C Y |
1,520 |
143 |
2574.508 |
FERTILIZER TYPE 3 |
LB |
670 |
144 |
2575.504 |
SODDING TYPE LAWN |
S Y |
9,110 |
145 |
2575.507 |
MULCH MATERIAL TYPE 6 |
C Y |
45 |
146 |
2575.523 |
RAPID STABILIZATION METHOD 3 |
MGAL |
12 |
147 |
2582.503 |
4" SOLID LINE MULTI-COMPONENT (WR) |
L F |
290 |
148 |
2582.503 |
12" SOLID LINE MULTI-COMPONENT (WR) |
L F |
145 |
149 |
2582.503 |
4" DOTTED LINE MULTI-COMPONENT (WR) |
L F |
326 |
150 |
2582.503 |
4" DOUBLE SOLID LINE MULTI-COMPONENT (WR) |
L F |
5,235 |
152 |
2582.518 |
PAVEMENT MESSAGE PREFORM THERMOPLASTIC GROUND IN CONTRAST |
S F |
322 |
|
2582.518 |
CROSSWALK MULTI-COMPONENT GROUND IN (WR) |
S F |
0 |
|
2582.518 |
PAVEMENT MESSAGE MULTI-COMPONENT GROUND IN (WR) |
S F |
0 |