Line |
Item Number |
Description |
Units |
Quantity |
Base Bid |
|
2021.501/00010 |
MOBILIZATION |
LS |
1 |
|
2101.502/00010 |
CLEARING |
TREE |
1 |
|
2101.507/00010 |
GRUBBING |
TREE |
1 |
|
2104.501/00016 |
REMOVE SEWER PIPE (STORM) |
L F |
251 |
|
2104.501/00022 |
REMOVE CURB AND GUTTER |
L F |
7,430 |
|
2104.505/00021 |
REMOVE CONCRETE WALK |
S Y |
966 |
|
2104.505/00108 |
REMOVE CONCRETE DRIVEWAY PAVEMENT |
S Y |
615 |
|
2104.505/00120 |
REMOVE BITUMINOUS PAVEMENT |
S Y |
1,980 |
|
2104.509/00013 |
REMOVE PIPE APRON |
EACH |
1 |
|
2104.509/00100 |
REMOVE MANHOLE OR CATCH BASIN |
EACH |
8 |
|
2104.511/00011 |
SAWING CONCRETE PAVEMENT (FULL DEPTH) |
L F |
1,690 |
|
2104.513/00011 |
SAWING BITUMINOUS PAVEMENT (FULL DEPTH) |
L F |
735 |
|
2104.523/00004 |
SALVAGE CASTING |
EACH |
3 |
|
2105.501/00010 |
COMMON EXCAVATION |
C Y |
100 |
|
2105.507/00010 |
SUBGRADE EXCAVATION |
C Y |
100 |
|
2105.522/00010 |
SELECT GRANULAR BORROW (LV) |
C Y |
100 |
|
2112.501 |
AGGREGATE GRADING AND COMPACTION |
STA |
74 |
|
2123.610/00045 |
STREET SWEEPER (WITH PICKUP BROOM) |
HOUR |
50 |
|
2130.501/00010 |
WATER |
MGAL |
20 |
|
2211.503/00050 |
AGGREGATE BASE (CV) CLASS 5 |
C Y |
100 |
|
2215.501/00010 |
FULL DEPTH RECLAMATION |
S Y |
15,750 |
|
2231.501/00010 |
BITUMINOUS PATCHING MIXTURE |
TON |
50 |
|
2331.603 |
SAW AND SEAL CONTROL JOINT IN BITUMINOUS PAVEMENT |
L F |
3,690 |
|
2331.607/00010 |
HAUL BITUMINOUS PAVEMENT RECLAMATION (LV) |
C Y |
1,910 |
|
2357.502/00010 |
BITUMINOUS MATERIAL FOR TACK COAT |
GAL |
1,260 |
|
2360.501/0002 |
TYPE SPWEA240B WEARING COURSE MIX PATHWAY |
TON |
430 |
|
2360.501/0006 |
TYPE SPWEA330C WEARING COURSE MIX |
TON |
2,500 |
|
2360.501/0009 |
TYPE SPWEA330C WEARING COURSE MIX (2018) |
TON |
1,500 |
|
2451.609/00030 |
GRANULAR BACKFILL |
TON |
7,130 |
|
2501.515/90180 |
"18" RC PIPE APRON" |
EACH |
1 |
|
2503.511/90125 |
"12" RC PIPE SEWER CLASS V" |
L F |
33 |
|
2503.511/90185 |
"18" RC PIPE SEWER CLASS V" |
L F |
54 |
|
2503.511/90245 |
"24" RC PIPE SEWER CLASS V" |
L F |
191 |
|
2503.602/00004 |
SANITARY SEWER SERVICE REPAIR |
EACH |
49 |
|
2503.602/00040 |
CONNECT TO EXISTING STRUCTURE |
EACH |
5 |
|
2503.602/00090 |
INSPECTION HOLE |
EACH |
12 |
|
2504.602/00012 |
REPAIR SERVICE CURB STOP BOX |
EACH |
20 |
|
2504.602/00013 |
ADJUST SERVICE CURB STOP BOX |
EACH |
6 |
|
2504.602/00015 |
REPAIR VALVE BOX |
EACH |
7 |
|
2504.602/00016 |
ADJUST VALVE BOX |
EACH |
24 |
|
2504.602/00017 |
REPLACE VALVE BOX |
EACH |
2 |
|
2504.602/00018 |
WATER UTILITY HOLE |
EACH |
5 |
|
2504.602/00019 |
EXCAVATION FOR WATER MAIN OFFSET OR REPLACEMENT |
EACH |
2 |
|
2504.602/00036 |
HYDRANT INSTALLATION |
EACH |
8 |
|
2504.602/00806 |
"6" GATE VALVE AND BOX" |
EACH |
4 |
|
2504.602/00808 |
"8" GATE VALVE AND BOX" |
EACH |
15 |
|
2504.603/00013 |
6" DI WATER MAIN REPLACEMENT |
L F |
60 |
|
2504.603/00018 |
8" DI WATER MAIN REPLACEMENT |
L F |
2,840 |
|
2504.603/00019 |
WATER SYSTEM REMOVALS |
L F |
568 |
|
2504.603/00026 |
1" CP WATER SERVICE REPLACEMENT |
L F |
89 |
|
2504.603/00027 |
2" CP WATER SERVICE REPLACEMENT |
L F |
24 |
|
2504.603/00028 |
2" CP WATER SERVICE REPLACEMENT - PIPE WORK ONLY |
L F |
195 |
|
2504.604/00050 |
"2" INSULATION" |
S Y |
56 |
|
2504.604/01100 |
"4" POLYSTYRENE INSULATION" |
S Y |
70 |
|
2504.608/00017 |
DUCTILE AND GREY IRON FITTINGS |
LB |
1,465 |
|
2506.502/05423 |
CONSTRUCT CATCH BASIN TYPE B |
L F |
17 |
|
2506.502/05428 |
CONSTRUCT CATCH BASIN TYPE A |
L F |
3 |
|
2506.502/05431 |
CONSTRUCT MANHOLE TYPE B OVER EXISTING PIPE |
L F |
5 |
|
2506.502/05440 |
CONSTRUCT MANHOLE TYPE C |
L F |
10 |
|
2506.502/05442 |
CONSTRUCT MANHOLE TYPE B |
L F |
10 |
|
2506.516/00011 |
MANHOLE CASTING R-1733 |
EACH |
21 |
|
2506.516/00012 |
MANHOLE CASTING R-3067-V |
EACH |
6 |
|
2506.521/00011 |
FURNISH AND INSTALL CASTING ASSEMBLY FOR DRIVEWAY |
EACH |
6 |
|
2506.522 |
ADJUST CATCH BASIN FRAME AND RING |
EA |
11 |
|
2506.522/00011 |
ADJUST MANHOLE FRAME & RING |
EACH |
39 |
|
2506.603 |
REHABILITATE MANHOLE OR CATCH BASIN (INTERIOR) |
EACH |
9 |
|
2511.501/00014 |
RANDOM RIPRAP CLASS III - GRANITE |
C Y |
60 |
|
2521.501/00040 |
"4" CONCRETE WALK" |
S F |
9,430 |
|
2521.501/00060 |
"6" CONCRETE WALK" |
S F |
2,985 |
|
2531.501/02315 |
CONCRETE CURB AND GUTTER DESIGN B618 |
L F |
4,680 |
|
2531.501/02317 |
CONCRETE CURB AND GUTTER DESIGN B618 (MACHINE LAID) |
L F |
2,750 |
|
2531.507/00060 |
"6" CONCRETE DRIVEWAY PAVEMENT" |
S Y |
615 |
|
2531.604/00108 |
"8" CONCRETE VALLEY GUTTER" |
S Y |
90 |
|
2531.618 |
TRUNCATED RADIUS DOMES |
S F |
184 |
|
2531.618/00010 |
TRUNCATED DOMES |
S F |
120 |
|
2563.601/00010 |
TRAFFIC CONTROL |
LS |
1 |
|
2573.502/00010 |
SILT FENCE, TYPE HI |
L F |
200 |
|
2573.530/00010 |
STORM DRAIN INLET PROTECTION |
EACH |
32 |
|
2573.533/00030 |
SEDIMENT CONTROL LOG TYPE COMPOST |
L F |
1,200 |
|
2573.550/00010 |
EROSION CONTROL SUPERVISOR |
LS |
1 |
|
2574.525/00050 |
BOULEVARD TOPSOIL BORROW |
C Y |
610 |
|
2575.505/00050 |
SODDING TYPE SALT TOLERANT |
S Y |
7,060 |
|
2575.604/00224 |
HYDROSEED |
SY |
500 |
|
2582.502/30104 |
"4" SOLID LINE EPOXY" |
L F |
330 |
Alternate 1 |
|
2104.501/00016 |
REMOVE SEWER PIPE (STORM) |
L F |
179 |
|
2501.515/90240 |
"24" RC PIPE APRON" |
EACH |
1 |
|
2503.511/90241 |
24" RC PIPE SEWER CLASS V (SPECIAL) |
L F |
179 |
|
2506.502/05440 |
CONSTRUCT MANHOLE TYPE C |
L F |
7 |
|
2506.516/00012 |
MANHOLE CASTING R-3067-V |
EACH |
1 |
|
2511.501/00014 |
RANDOM RIPRAP CLASS III - GRANITE |
C Y |
60 |
|
2571.502/06250 |
"DECIDUOUS TREE 2.5" CAL B&B" |
TREE |
1 |
Alternate 2 |
|
2501.515/20180 |
"18" GS PIPE APRON" |
EACH |
1 |
|
2503.511/90245 |
"24" RC PIPE SEWER CLASS V" |
L F |
4 |
|
2503.603/06181 |
"18" HDPE PIPE SEWER-DIRECTIONAL DRILLED" |
L F |
179 |
|
2506.502/05442 |
CONSTRUCT MANHOLE TYPE B |
L F |
14 |
|
2506.516/00012 |
MANHOLE CASTING R-3067-V |
EACH |
2 |