Line |
Item Number |
Description |
Units |
Quantity |
|
1506.601/00001 |
PROJECT SUPERINTENDENCE |
LS |
1 |
|
2021.501/00010 |
MOBILIZATION |
LS |
1 |
|
2101.524/00040 |
CLEARING |
TREE |
10 |
|
2101.524/00050 |
GRUBBING |
TREE |
10 |
|
2104.502/00780 |
REMOVE MANHOLE |
EACH |
22 |
|
2104.502/00790 |
REMOVE CATCH BASIN |
EACH |
34 |
|
2104.502/00820 |
REMOVE CASTING |
EACH |
41 |
|
2104.502/00850 |
REMOVE GATE VALVE & BOX |
EACH |
19 |
|
2104.502/00880 |
REMOVE HYDRANT |
EACH |
15 |
|
2104.502/01960 |
SALVAGE CASTING |
EACH |
19 |
|
2104.502/03300 |
SALVAGE SIGN |
EACH |
11 |
|
2104.503/00122 |
REMOVE BITUMINOUS TRAIL PAVEMENT |
S Y |
46 |
|
2104.503/00124 |
REMOVE BITUMINOUS PAVEMENT (RANDOM) |
SY |
1,218 |
|
2104.503/00195 |
SAWING CONCRETE PAVEMENT (FULL DEPTH) |
L F |
3,026 |
|
2104.503/00205 |
SAWING BIT PAVEMENT (FULL DEPTH) |
L F |
5,534 |
|
2104.503/00270 |
REMOVE WATER MAIN |
L F |
5,770 |
|
2104.503/00285 |
REMOVE SEWER PIPE (STORM) |
L F |
1,257 |
|
2104.503/00290 |
REMOVE SEWER PIPE (SANITARY) |
L F |
208 |
|
2104.503/00315 |
REMOVE CURB & GUTTER |
L F |
18,600 |
|
2104.503/00350 |
REMOVE RETAINING WALL |
L F |
50 |
|
2104.503/00870 |
REMOVE GAS MAIN |
L F |
3,000 |
|
2104.504/00110 |
REMOVE BITUMINOUS DRIVEWAY PAVEMENT |
S Y |
601 |
|
2104.504/00111 |
REMOVE BITUMINOUS PAVEMENT (FULL DEPTH) |
SY |
31,953 |
|
2104.518/00130 |
REMOVE CONCRETE SIDEWALK |
S F |
14,212 |
|
2104.518/00200 |
REMOVE CONCRETE PAVEMENT |
S F |
15,977 |
|
2104.523/60409 |
SALVAGE CITY LIGHT POLE |
EACH |
1 |
|
2104.618/00100 |
SALVAGE PAVERS |
SF |
508 |
|
2105.507/00015 |
COMMON EXCAVATION |
C Y |
11,091 |
|
2105.507/00050 |
SUBGRADE EXCAVATION |
C Y |
6,000 |
|
2105.507/00380 |
COMMON BORROW (CV) |
C Y |
6,000 |
|
2112.519/00020 |
SUBGRADE PREPARATION 6"-12" |
RDST |
110 |
|
2123.610/00410 |
STREET SWEEPER (WITH PICKUP BROOM) |
HOUR |
400 |
|
2211.509/00070 |
AGGREGATE BASE CLASS 5 |
TON |
15,526 |
|
2231.100/60002 |
BITUMINOUS PATCHING (RANDOM) |
SY |
361 |
|
2231.100/60003 |
BITUMINOUS PATCHING (RANDOM) |
TON |
361 |
|
2232.504/00129 |
EDGE MILL BITUMINOUS SURFACE (0" TO 1.5") |
SY |
14,615 |
|
2232.504/00130 |
MILL BITUMINOUS SURFACE (3.5") |
S Y |
11,984 |
|
2357.506/00010 |
BITUMINOUS MATERIAL FOR TACK COAT |
GAL |
5,834 |
|
2360.509/12200 |
TYPE SP 9.5 WEARING COURSE MIX (2;B) |
TON |
84 |
|
2360.509/22200 |
TYPE SP 12.5 WEARING COURSE MIX (2;B) |
TON |
11,270 |
|
2433.603/60410 |
SAW AND SEAL TRANSVERSE CRACK CONTROL JOINT |
L F |
11,000 |
|
2503.503/13100 |
10" PVC PIPE SEWER |
L F |
201 |
|
2503.503/15125 |
12" RC PIPE SEWER CLASS V |
L F |
490 |
|
2503.503/15155 |
15" RC PIPE SEWER CLASS V |
L F |
269 |
|
2503.503/15185 |
18" RC PIPE SEWER CLASS V |
L F |
250 |
|
2503.503/15245 |
24" RC PIPE SEWER CLASS V |
L F |
141 |
|
2503.503/15484 |
48" RC PIPE SEWER CLASS IV |
L F |
29 |
|
2503.602/60144 |
CONNECT TO EXISTING STRUCTURE |
EACH |
7 |
|
2503.602/60145 |
CONNECT INTO EXISTING SEWER PIPE |
EACH |
12 |
|
2503.603/60150 |
SANITARY SEWER SERVICE REPAIR |
L F |
1,320 |
|
2503.608/00011 |
DUCTILE IRON FITTINGS |
LB |
1,650 |
|
2504.601/00040 |
TEMPORARY WATER SERVICE |
LS |
1 |
|
2504.602/00010 |
CONNECT TO EXISTING WATER MAIN |
EACH |
14 |
|
2504.602/00020 |
HYDRANT |
EACH |
15 |
|
2504.602/00033 |
ADJUST GATE VALVE |
EACH |
36 |
|
2504.602/00410 |
1" CORPORATION STOP |
EACH |
132 |
|
2504.602/00806 |
6" GATE VALVE & BOX |
EACH |
34 |
|
2504.602/03700 |
1" CURB STOP |
EACH |
132 |
|
2504.603/00710 |
1" TYPE K COPPER PIPE |
L F |
2,970 |
|
2504.603/01062 |
6" WATERMAIN DUCTILE IRON CL 52 |
L F |
5,890 |
|
2504.604/01050 |
2" POLYSTYRENE INSULATION |
S Y |
200 |
|
2506.502/60004 |
CONSTRUCT DRAINAGE STRUCTURE, TYPE "B" |
EACH |
33 |
|
2506.502/60006 |
CONSTRUCT DRAINAGE STRUCTURE, TYPE "C", DES 48" |
EACH |
22 |
|
2506.502/60009 |
CONSTRUCT DRAINAGE STRUCTURE, TYPE "SAFL BAFFLE" |
EACH |
3 |
|
2506.502/66000 |
CASTING ASSEMBLY (NEENAH R-3067) |
EACH |
20 |
|
2506.502/66001 |
CASTING ASSEMBLY (NEENAH R-1733) |
EACH |
20 |
|
2506.502/66002 |
CASTING ASSEMBLY (TYPE A-1) |
EACH |
50 |
|
2506.521/60101 |
INSTALL CASTING ASSEMBLY (NEENAH R-3067) |
EACH |
26 |
|
2506.521/60102 |
INSTALL CASTING ASSEMBLY (NEENAH R-1733) |
EACH |
35 |
|
2506.521/99999 |
INSTALL CASTING ASSEMBLY (TYPE A-1) |
EACH |
50 |
|
2506.602/06100 |
ADJUST FRAME & RING CASTING |
EACH |
48 |
|
2506.602/90001 |
RECONSTRUCT SANITARY SEWER STRUCTURE |
L F |
72 |
|
2506.602/99998 |
REHABILITATE MANHOLE OR CATCH BASIN (INTERIOR) |
EACH |
13 |
|
2521.518/00040 |
4" CONCRETE WALK |
S F |
16,613 |
|
2521.518/00060 |
6" CONCRETE WALK |
S F |
7,045 |
|
2531.503/02315 |
CONCRETE CURB & GUTTER DESIGN B618 |
L F |
18,924 |
|
2531.503/19215 |
CONCRETE CURB & GUTTER DESIGN S518 |
L F |
100 |
|
2531.504/00060 |
6" CONCRETE DRIVEWAY PAVEMENT |
SF |
17,820 |
|
2531.504/00080 |
8" CONCRETE DRIVEWAY PAVEMENT |
SF |
572 |
|
2531.618/00010 |
TRUNCATED DOMES |
S F |
423 |
|
2540.618/00085 |
INSTALL PAVERS |
SF |
508 |
|
2545.503/01053 |
2" NON-METALLIC CONDUIT |
L F |
100 |
|
2545.602/60054 |
INSTALL CITY LIGHT POLE |
EACH |
1 |
|
2563.601/00010 |
TRAFFIC CONTROL |
LS |
1 |
|
2564.602/01515 |
INSTALL SIGN |
EACH |
11 |
|
2572.503/00030 |
CLEAN ROOT CUTTING |
L F |
500 |
|
2572.602/00015 |
TREE PRUNING |
HOUR |
75 |
|
2573.501/00030 |
EROSION CONTROL SUPERVISOR |
LS |
1 |
|
2573.502/00110 |
STORM DRAIN INLET PROTECTION |
EACH |
137 |
|
2573.503/00023 |
SILT FENCE; TYPE MS |
L F |
1,000 |
|
2573.503/00060 |
SEDIMENT CONTROL LOG TYPE STRAW |
L F |
250 |
|
2573.602/00021 |
TEMPORARY CONSTRUCTION ENTRANCE |
EACH |
12 |
|
2574.507/00105 |
MODIFIED TOPSOIL BORROW |
CY |
2,437 |
|
2574.508/00013 |
FERTILIZER TYPE 3 |
LB |
698 |
|
2575.504/00011 |
SODDING TYPE LAWN |
S Y |
16,887 |
|
2575.508/40001 |
HYDRAULIC MULCH MATRIX |
LB |
2,000 |
|
2575.535/00013 |
WATER (SOD) |
MGAL |
564 |
|
2582.518/08020 |
CROSSWALK PREF THERMO GR IN |
S F |
270 |