Line |
Item Number |
Description |
Units |
Quantity |
SAP 032-599-104 |
|
2021.501/00010 |
MOBILIZATION |
LS |
1 |
|
2104.503/00265 |
REMOVE METAL CULVERT |
L F |
85 |
|
2105.507/00015 |
COMMON EXCAVATION |
C Y |
380 |
|
2105.507/00380 |
COMMON BORROW (CV) |
C Y |
419 |
|
2118.509/00050 |
AGGREGATE SURFACING CLASS 5 |
TON |
428 |
|
2360.509/12200 |
TYPE SP 9.5 WEARING COURSE MIX (2;B) |
TON |
68 |
|
2401.601/00010 |
STRUCTURE EXCAVATION |
LS |
1 |
|
2401.601/00060 |
SLOPE PREPARATION |
LS |
1 |
|
2402.508/00010 |
STRUCTURAL STEEL (3306) |
LB |
2,586 |
|
2403.502/00510 |
PREFABWOOD PANELS TYPE A28 |
EACH |
4 |
|
2403.502/00511 |
PREFAB WOOD PANELS TYPE B28 |
EACH |
4 |
|
2403.502/00512 |
PREFAB WOOD PANELS TYPE C28 |
EACH |
12 |
|
2403.508/00010 |
HARDWARE |
LB |
6,827 |
|
2403.603/00020 |
TIMBER RAILING |
L F |
224 |
|
2403.622/00020 |
TREATED TIMBER |
MBM |
11.57 |
|
2442.501/00010 |
REMOVE EXISTING BRIDGE |
LS |
1 |
|
2452.502/02080 |
C-I-P CONC TEST PILE 80 FT LONG 12" |
EACH |
2 |
|
2452.502/03090 |
C-I-P CONC TEST PILE 90 FT LONG 16" |
EACH |
3 |
|
2452.502/20050 |
PILE POINTS 12" |
EACH |
12 |
|
2452.502/20060 |
PILE POINTS 16" |
EACH |
15 |
|
2452.503/01000 |
TREATED TIMBER PILING DELIVERED |
L F |
100 |
|
2452.503/01200 |
TREATED TIMBER PILING DRIVEN |
L F |
100 |
|
2452.603/06120 |
C-I-P CONCRETE PILING 12" |
L F |
700 |
|
2452.603/06160 |
C-I-P CONCRETE PILING 16" |
L F |
960 |
|
2501.502/04015 |
15" GS PIPE APRON |
EACH |
4 |
|
2501.503/12015 |
15" CS PIPE CULVERT |
L F |
120 |
|
2511.504/00017 |
GEOTEXTILE FILTER TYPE 7 |
S Y |
710 |
|
2511.509/00015 |
RANDOM RIPRAP CLASS V |
TON |
700 |
|
2563.601/00010 |
TRAFFIC CONTROL |
LS |
1 |
|
2573.503/00023 |
SILT FENCE; TYPE MS |
L F |
330 |
|
2573.503/00031 |
FLOTATION SILT CURTAIN TYPE MOVING WATER |
L F |
220 |
|
2573.503/00060 |
SEDIMENT CONTROL LOG TYPE STRAW |
L F |
1,300 |
|
2573.503/00065 |
SEDIMENT CONTROL LOG TYPE ROCK |
L F |
90 |
|
2575.504/00110 |
RAPID STABILIZATION METHOD 4 |
S Y |
1,500 |
SAP 032-599-108 |
|
2021.501/00010 |
MOBILIZATION |
LS |
1 |
|
2101.501/00020 |
CLEARING & GRUBBING |
LS |
1 |
|
2105.507/00015 |
COMMON EXCAVATION |
C Y |
335 |
|
2118.509/00050 |
AGGREGATE SURFACING CLASS 5 |
TON |
374 |
|
2360.509/12200 |
TYPE SP 9.5 WEARING COURSE MIX (2;B) |
TON |
54 |
|
2401.601/00010 |
STRUCTURE EXCAVATION |
LS |
1 |
|
2401.601/00060 |
SLOPE PREPARATION |
LS |
1 |
|
2402.508/00010 |
STRUCTURAL STEEL (3306) |
LB |
5,497 |
|
2403.502/00513 |
PREFAB WOOD PANELS TYPE A30 |
EACH |
3 |
|
2403.502/00513 |
PREFAB WOOD PANELS TYPE B30 |
EACH |
3 |
|
2403.502/00514 |
PREFAB WOOD PANELS TYPE C30 |
EACH |
12 |
|
2403.508/00010 |
HARDWARE |
LB |
4,697 |
|
2403.603/00020 |
TIMBER RAILING |
L F |
180 |
|
2403.622/00020 |
TREATED TIMBER |
MBM |
10.022 |
|
2442.501/00010 |
REMOVE EXISTING BRIDGE |
LS |
1 |
|
2452.502/02060 |
C-I-P CONC TEST PILE 60 FT LONG 12" |
EACH |
2 |
|
2452.502/03055 |
C-I-P CONC TEST PILE 55 FT LONG 16" |
EACH |
2 |
|
2452.502/20050 |
PILE POINTS 12" |
EACH |
12 |
|
2452.502/20060 |
PILE POINTS 16" |
EACH |
12 |
|
2452.503/01000 |
TREATED TIMBER PILING DELIVERED |
L F |
200 |
|
2452.503/01200 |
TREATED TIMBER PILING DRIVEN |
L F |
200 |
|
2452.603/06120 |
C-I-P CONCRETE PILING 12" |
L F |
500 |
|
2452.603/06160 |
C-I-P CONCRETE PILING 16" |
L F |
450 |
|
2501.502/04015 |
15" GS PIPE APRON |
EACH |
2 |
|
2501.503/12015 |
15" CS PIPE CULVERT |
L F |
60 |
|
2511.504/00017 |
GEOTEXTILE FILTER TYPE 7 |
S Y |
590 |
|
2511.509/00013 |
RANDOM RIPRAP CLASS III |
TON |
435 |
|
2563.601/00010 |
TRAFFIC CONTROL |
LS |
1 |
|
2573.503/00023 |
SILT FENCE; TYPE MS |
L F |
984 |
|
2573.503/00031 |
FLOTATION SILT CURTAIN TYPE MOVING WATER |
L F |
200 |
|
2575.501/00020 |
TURF ESTABLISHMENT |
LS |
1 |
|
2575.604/01120 |
ROLLED EROSION PREVENTION CATEGORY 20 |
S Y |
638 |